Omron 61F-GP-N8 200VAC

memberiso
  • Part Number:

    61F-GP-N8 200VAC

  • Manufacturer:

    Omron

  • Category:

    PLC Modules

  • RoHs:

    rohs Non-RoHS Compliant

  • Datasheet:

  • Description:

    CNTRL LIQ LEV SOCKETABLE

  • In stock 0
" Not available to buy online? Want the lower wholesale price? Please send RFQ, we will respond immediately
Contact Name
Business Email
Company Name
Country
Quantity
Email

Leave Us A Message!

We`re not around but we still want to hear from you! Leave us a note:

SEND
EmailWhatsApp
*You can contact us directly on WhatsApp!
Specifications
Type
Paramete
Type
Paramete
Output Type
-
Type
-
Contact Rating @ Voltage
-
Operating Temperature
-
Sensitivity
-
Contact Form
-
Mounting Type
-
Features
-
Termination Style
-
Distance - Control To Sensor (Max)
-
Voltage - Supply
-
Overview

Information of Floatless Level Switch Model 61F-GP-N8 200VAC


1. Basic Product Information


1.1 Product Category

Floatless Level Switch (Compact, Plug-in Type)


1.2 Manufacturer

Omron Corporation


1.3 Core Function

Designed for automatic water supply and drainage control of ordinary purified water or sewage water. It uses electrode detection to trigger switching actions, with an LED indicator for operating status monitoring.


1.4 Key Features


  • Compact Design: Space-saving (specific dimensions detailed in Section 7), ideal for control panel downsizing.
  • Easy Maintenance: Plug-in structure facilitates installation and replacement.
  • Status Indication: LED operation indicator enables easy identification of working status.
  • Wide Voltage Compatibility: Rated supply voltage 200VAC (50/60Hz), operating voltage range 85%–110% of rated voltage.
  • Compliance: CE marking, UL/CSA compliance, meeting industrial electromagnetic environment standards (EN61010-1, EN61326-1).

2. Ordering & Model Details


2.1 Model Explanation


  • Model Number: 61F-GP-N8 200VAC

2.2 Accessory


  • Standard Accessory: Hold-down clip PFC-N8 (for mounting to sockets).

3. Electrical Specifications


ParameterSpecifications
Supply Voltage200VAC, 50/60Hz
Operating Voltage Range85% to 110% of rated voltage (170VAC–220VAC)
Interelectrode Voltage8VAC
Interelectrode CurrentMax. approx. 1mA AC
Power ConsumptionMax. approx. 3.5VA
Interelectrode Operate Resistance0 to approx. 4kΩ
Interelectrode Release ResistanceApprox. 15kΩ to ∞Ω
Response TimeOperate: Max. 80ms; Release: Max. 160ms
Control Output1A, 250VAC (Inductive load: cosφ = 0.4); 3A, 250VAC (Resistive load)
Insulation ResistanceMin. 100MΩ (at 500VDC)
Dielectric Strength2000VAC, 50/60Hz for 1min (between power terminals & electrode terminals, power terminals & contact terminals, electrode terminals & contact terminals)
Life ExpectancyElectrical: Min. 100,000 operations; Mechanical: Min. 5,000,000 operations

4. Environmental Specifications


ParameterSpecifications
Operating Ambient Temperature–10°C to 55°C
Operating Ambient Humidity45% to 85% RH
Cable Length (Max.)1km (when using completely insulated, 600-V, 3-conductor (0.75mm²) cabtire cables; usable length decreases with larger cable diameter or more conductors)
WeightApprox. 155g

5. Application Scope


  • Controlling Materials: Ordinary purified water or sewage water.
  • Typical Applications: Automatic water supply control, automatic drainage control, liquid level indication systems, and other scenarios requiring liquid level monitoring and switching control.

6. Wiring & Connection


6.1 Connection Sockets


  • Front-connecting: PF083A
  • Rear-connecting: PL08

6.2 Key Connection Diagrams


6.2.1 Automatic Water Supply Control


  • Power Supply: Commercial voltage (200VAC) connected via MCCB.
  • Control Circuit: 24V control circuit, power supply provides 8V for electrodes.
  • Wiring Notes: Connect terminal 2 to the contactor’s coil terminal; ground the common electrode E3 (longest electrode).

6.2.2 Automatic Drainage Control


  • Power Supply: Commercial voltage (200VAC) connected via MCCB.
  • Control Circuit: 24V control circuit, power supply provides 8V for electrodes.
  • Wiring Notes: Connect terminal 3 to the contactor’s coil terminal; ground the common electrode E3 (longest electrode).

6.2.3 Three-phase Four-line Circuit Connection


  • Line Voltage: 380 or 415VAC; Phase Voltage (N-R/N-S/N-T): 220 or 240VAC (compatible with 200VAC rated voltage).
  • Wiring Notes: Power supply is taken from N-phase and one line phase; ground terminal 1; adjust terminal connections (terminal 2 for water supply, terminal 3 for drainage) based on application.

6.3 Operating Principles


  • Water Supply Control: The pump stops when the water level reaches E1 (LED indicator ON) and starts when the water level drops below E2 (LED indicator OFF).
  • Drainage Control: The pump starts when the water level reaches E1 (LED indicator ON) and stops when the water level drops below E2 (LED indicator OFF).

7. Mechanical Dimensions (Unit: mm)


  • Overall Dimensions: Refer to the "Dimensions" section of the original document.
  • Mounting: Use the provided PFC-N8 mounting bracket to mount the level controller to PF083A rail-mounted sockets.
  • Key Dimensions: 91mm (length) × 70mm (width) (specific detailed dimensions follow the original drawing; all units are in millimeters).

8. Safety & Usage Precautions


  1. Cable Selection: Use completely insulated, 600-V, 3-conductor (0.75mm²) cabtire cables; avoid exceeding the maximum recommended cable length.
  2. Grounding Requirement: Ensure reliable grounding of the common electrode E3 (longest electrode) and specified terminals to prevent electrical hazards.
  3. Insulation & Dielectric Strength: Comply with the specified insulation resistance and dielectric strength requirements; avoid operating in environments that may damage insulation.
  4. Environmental Limits: Do not use beyond the specified operating temperature and humidity ranges to ensure stable performance.
  5. Application Restriction: Not suitable for applications involving serious risk to life or property without proper system-level risk mitigation design.
  6. Specification Changes: Product specifications are subject to change without notice; confirm actual specifications before use.


Shopping Guide
Purchase

No need to register to order from JMBom Electronics, but signing in lets you track your order like a pro. Give it a try for a smoother shopping ride.

Means

Easy peasy! Pay your way with PayPal, Credit Card, or wire transfer in USD. We've got you covered.

RFQ(Request for Quotations)

Get the freshest prices and stock updates by asking for a quote! Our sales team will shoot you an email within a day. It's that simple.

IMPORTANT NOTICE

1. Look out for your order details in your inbox! (If it's missing, check the spam folder just in case.)

2. Our sales manager will double-check the order and keep you posted on any price or stock changes. No worries, we've got you covered. 

picture_01

Shipping Rate

We ship orders once a day around 5 p.m., except Sunday. Once shipped, the estimated delivery time depends on the courier company you choose, usually 5-7 working days.

picture_02

Shipping Methods

We provide DHL, FedEx, UPS, EMS, SF Express, and Registered Air Mail international shipping.

picture_11
picture_03

Payment

You can pay the orders on the website directly or pay by wire transfer offline. We support: Paypal、VISA、Credit Card.

pay-img-1pay-img-2pay-img-3pay-img-4
Related Product By Brand